精品二区中文字幕播放-精品二区在线观看-精品二区一国产va-精品二区三区三级日韩人妖-精品二区三区-精品二区蜜芽

current location:Home>Products>Spectroscopy>Lock-In Amplifiers

OE1022 Digital Lock-In Amplifiers
    Now OE1022 DSP Lock-In Amplifier is the newest product of core technology with high performance. Based on the digital demodulation, output filter and high-precision stabilized 24-bit ADC, it is ideal to detect the weak signals, which are overwhelmed by greatly larger noise components. And OE1022 could measure the magnitude and phase of a signal simultaneously. It could be comparable with the international leading technology in some core parameters, like accuracy of measurement, range of operating frequency, SNR, dynamic reserve and so on. Meanwhile, we have integrated other functions like multiple-harmonic measurement and FFT in OE1022, which makes this DSP Lock-In Amplifier could meet the needs of scientific research and industrial purposes.
  • description
  • parameters

OE1022 Digital Lock-In Amplifiers


Overview

Now OE1022 DSP Lock-In Amplifier is the newest product of core technology with high performance. Based on the digital demodulation, output filter and high-precision stabilized 24-bit ADC, it is ideal to detect the weak signals, which are overwhelmed by greatly larger noise components. And OE1022 could measure the magnitude and phase of a signal simultaneously. It could be comparable with the international leading technology in some core parameters, like accuracy of measurement, range of operating frequency, SNR, dynamic reserve and so on. Meanwhile, we have integrated other functions like multiple-harmonic measurement and FFT in OE1022, which makes this DSP Lock-In Amplifier could meet the needs of scientific research and industrial purposes.


Input Channel

With the low-noise analog pre-amplifier, the signal input of OE1022 can be switched to operate in the single-ended or differential voltage mode, and the input noise is 10 nV/√Hz. The input impedance is 10 M? and the full-scale input voltage sensitivity ranges from 1 nV to 1V. Besides, OE1022 can also be used for current measurements with variable current gains of 10 or 10 V/A. Two line filters (50/60 Hz and 100/120 Hz) are designed to eliminate line related interference. The programmable gain amplifier is provided to adjust the dynamic reserve of the system according to the magnitude of the input signal, so that OE1022 has inherently large dynamic reserve up to 100dB. The sampling rate of 312.5KSPS is determined by a precision 24-bit A/D converter and a specific filter is designed to avoid aliasing.


Reference Channel

In order to provide the reference signal for OE1022, an externally applied sine wave or square wave, or its owninternally synthesized reference source could be used. When the instrument is set to internal reference mode, the internal precision stabilized oscillator and the digital synthesized algorithm are used to generate sinewave output that multiplies the input signal, there is virtually no reference phase noise when choosing internal reference mode. Taking advantage of digital phase-shifting technique, the reference signal phase could be adjusted with 0.01° resolution. The
internal reference mode can operate at a fixed frequency from 1 mHz to 100 kHz. In addition, the external reference is also applicable to OE1022, including the sinewave reference signal and TTL logic reference signal. The rising and trailing edge of external reference signal are applied to trigger off the internal Phase Locking Loop (PLL). Based on the frequency of reference signal, harmonic detection can be performed by OE1022. The maximum frequency of the measurable harmonics is 32767 times of basic frequency, and it is also less than the maximum operational frequency 100 kHz.


Digital Demodulator and Output Filter

The core of Lock-In Amplifier OE1022 is demodulator. This digital demodulator could be effectively immune from the potential errors caused by DC drift and offset found in analog multipliers or switches. The coherent signal multiplication has been optimized for very low calculation error. The time constants of OE1022 could be configured extending from 10 μs to 30 ks. The roll-offs of the output low-pass filter on OE1022 are 6, 12, 18 and 24 dB/octave. This low-pass filter is carried out by the architecture of digital infinite impulse response (IIR) filters and updated at 312.5 kHz signal
sampling rate. The advantages of this design over common analog instruments are higher dynamic reserve (>100dB), accurate phase shifts (absolute phase error <1°), zero drift, and orthogonality. Meanwhile, below 200 Hz, OE1022 can perform synchronous filtering, which is used to notch out
multiples of the reference frequency. This function ensures that OE1022 works quickly at low frequency.

Display

OE1022 uses the 5.6 inch 640×480 TFT color display as its screen. Data measured by OE1022, such as, X, Y, R, θ, is stored in up to four traces. Trace values can be displayed as a bar graph or as a strip chart showing the trace values as a function of time.

                                                  

OE1022 can also show the relationship of time and range in a XY graph and you can check the value of sampling point by using knob control cursor.

                                                   

Besides, OE1022 can display polar plots, showing phasor composed by in-phase and quadrature components of the signal. All displays can be easily scaled by the manual operation, and the auto-scale feature is available to optimize display quickly. The screen can be configured as a single large display, or two horizontally-split displays.

                                                     

FFT Spectral analysis
In order to analyze the noise component in signal, we have developed FFT high precision spectral analysis function and integrate it in OE1022, which can ensure high precision frequency measurement between 1kHz to 100kHz, while displaying the spectrum distribution of signal in real time.


Simultaneous Multiple-harmonic Measurement

The traditional phase-locked amplifier can only measure fundamental frequency signal or one certain harmonic ware at the same time, so it can not meet the requirement in some occasions when measuring multiple frequency components simultaneously is needed. In digital end, OE1022 combined FPGA and ARM technology, which has wider processing bandwidth and more flexible digital framework. The digital processing precision could reach 48 bits and could measure 3-channal harmonic components simultaneously, which makes one OE1022 is equal to three traditional phase-locked amplifiers.


Internal Oscillator
The internal oscillator helps to generate a very low distortion (–80 dBc) reference signal. The single frequency of sine waves can be extended from 1 mHz to 100 kHz while the resolution generated is 0.1 mHz. Both frequency and amplitude can be set from the front panel or a computer. When choosing external reference mode, the internal oscillator is phase-locked to the external reference signal.

Signal Generator
OE1022 generates one sinusoidal signal in range from 1 mHz to 100 kHz, using 20-bit D/A converter. The frequency and phase shift of this sinusoidal signal are corresponding to that of the internal reference signal, and its amplitude could be set with control menu. The maximum amplitude provided by signal generator is 5Vrms.


Manual Operation
In addition to displaying data, the color TFT display panel is also used to display the control menu. In conjunction with keys grouped around the screen and numeric keypad, customers could adjust instrument's parameters effectively, such as oscillator frequency, which can be set to a fixed value
and to a high precision.


Auto Function
OE1022 has the ability to adjust measurement parameters to optimum setting for input signal. Gain, phase, dynamic reserve and display scaling could all be set with different independent key presses from the control menu. With this function, the input signals could be measured easily and automatically.

Interface
OE1022 regards RS-232 to USB interfaces as standard. And, all instrument functions can be controlled and read through USB interfaces. To debug conveniently, all of the interfaces could be viewed on front panel. For convenient debugging, characters received and sent via interfaces can be viewed on front panel.


Remote Operation
The built-in RS232 to USB interfaces on OE1022 allow full manual operation from a controlling computer, including setting or interrogating control and reading out data. Free LabVIEW program is provided. It makes it easy to set up and run complex experiments, such as remote control of every instrument function. The display menu offered by the LabVIEW program allows customers observe all command received and responses generated by instrument.
                       


Signal Channel
Voltage input Mode  Single-ended or Differential
Full-scale Sensitivity 1nV to 1 V in a 1-2-5 sequence
Current input  10 or 10 V/A
Impedance
Voltage  10 MΩ // 25pF, AC or DC
coupled
Current  1kΩ to virtual ground
C.M.R.R  >100 dB to 10 KHz, decreasing
by 6 dB/oct
Dynamic reserve >100 dB
Gain accuracy  0.2% typ, 1% max
Noise 10nV/√Hz at 1 kHz
0.13pA/√Hz at 1 kHz
0.013pA/√Hz at 100 Hz
Line filters 50/60 Hz and 100/120 Hz
Gounding BNC shield can be grounded

or floated via 1kΩ to ground


Reference Channel
Input
Frequency range 1 mHz to 100 kHz
Reference input TTL or sine
Input impedance 1 MΩ//25 pF
Phase
Resolution 0.01° increments
Absolute phase error  <1°
Relative phase error  <0.01°
Orthogonality  90°±0.001°
Phase noise
Internal ref. Synthesized, <0.0001°rms at
1kHz
External ref.  0.005°rms at 1 kHz (100 ms
time constant, 12 dB/oct)
Drift <0.01°/℃ below 10 kHz
<0.1°/℃ above 10 kHz
Harmonic detection  2F, 3F, …nF to 100kHz
(n<32,767)
Acquisition time
Internal Ref.  Instantaneous acquisition
External Ref.  (2 cycles + 5 ms) or 40 ms,
whichever is larger



Demodulator
Stability
Digital outputs  no zero drift on all setting
Display no zero drift on all setting
Analog outputs <5 ppm/℃ for all dynamic
reserve settings
Harmonic rejection  -90 dB
Time constants 10μs to 3ks (<200Hz)
10μs to 30s (>200Hz)
(6, 12, 18, 24 dB/oct rolloff)
Synchronous filters  Available below 200 Hz and 18,24 dB/oct


Internal Oscillator
Frequency
Range  1 mHz to 100 kHz
Accuracy 25 ppm + 30 μHz
Resolution 1 mHz
Distortion -80 dBc (f<10 kHz),
-70 dBc (f>10 kHz)
Amplitude 0.001 to 5 Vrms
Accuracy 1%
Stability  50 ppm/℃
Outputs  Sine, 50 Ω output impedance

Display
Screen  5.6 inch, 640×480 TFT
Screen format  Single or dual display
Display quantities  Each display shows one trace,traces can be defined as X,Y,R,θ
Display types  Large numeric readout, bar graph, polar plot and strip chart


Outputs
CH1 and CH2 Outputs
Function  X, Y, R, θ
Amplitude ±10 V
Impedance 100 Ω

Interfaces
RS-232 to USB interfaces. All instrument functions can be controlled and read through USB interfaces.


General
Power requirements
Voltage  220/240V AC
Frequency 50/60 Hz
Power  40 W
Dimensions
Width  473 mm
Depth  490 mm
Height
With feet 160 mm
Without feet  147 mm
Weight  11. 9 KG


主站蜘蛛池模板: 欧美97色 | 色综合欧美 | 久久视频在线视频观品15 | 黄色18网站 | 免费高清毛片天天看 | 亚洲欧美偷拍视频一区 | 亚洲人精品午夜射精日韩 | 国产日韩精品一区二区在线观看 | 国产91一区二区在线播放不卡 | 六月丁香在线播放 | 久久国产片 | 久久久久女人精品毛片九一 | 无码中文字幕热热久久 | 久久五月天综合网 | 最刺激的长篇乱惀小说 | 99久久精品国语对白 | 欧洲无人区码SUV | 亚洲午夜无码毛片AV久久小说 | 日韩亚洲制服丝袜中文字幕 | www亚洲免费| 久就热视频精品免费99 | 国精产品999永久中国有限公司 | 中文字乱码电影在线播放 | 伦韩国理片在线观看 | 日本不卡视频在线播放 | 欧美黑人巨大性极品hd欧 | 区久久AAA片69亚洲 | 国产ZLJZLJZLJZLJ18公司 | 最新精品亚洲成a人在线观看 | 和漂亮老师做爰5中文字幕 黑巨茎大战俄罗斯白人美女 | 涩涩爱涩涩片影院 | 成年片色情大免费网站 | 国产综合在线观看 | 午夜精品久久久内射近拍高清 | 五月婷香| 国产亚洲精品第一综合另类 | 亚洲国产精品久久久久秋霞影院 | 亚洲精品久久久久一区二区 | 亚洲产国偷V产偷V自拍A片 | 国产精品免费看久久久 | 欧美日韩第二页 |